Special Design for Load Bank Controller - Crowbar/Chopper Resistor – Wepower

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Having a positive and progressive attitude to customer's fascination, our organization constantly improves our solution high-quality to fulfill the requirements of shoppers and further focuses on safety, reliability, environmental prerequisites, and innovation of Aluminum Oxide Corrosion Resistance, Ac Load Bank, Grounded Resistor On Input, We, with great passion and faithfulness, are willing to provide you with perfect services and striding forward with you to create a bright future.
Special Design for Load Bank Controller - Crowbar/Chopper Resistor – Wepower Detail:

█ Application

Crowbar resistor is mainly used in low voltage ride through technology of wind power inverter. It is used at the rotor side of wind turbine generator to bypass the rotor side converter. In case of low voltage disturbance in the power grid, the DC bus voltage and rotor current shall be prevented from being too high. It mainly works in fault state to damp stator flux linkage. Crowbar resistors can dissipate huge amounts of energy instantaneously.

It is mainly used in the frequency conversion / converter system of doubly fed variable speed constant frequency generator units to improve the low voltage ride through capability of generator units, which is limited by the power grid
Large current impact caused by voltage drop protects excitation converter and limits rotor winding over voltage.

█ Feature:

The resistance material is imported alloy steel, which can absorb large energy impact in a short time, and can meet different power requirements.

█ structures:

Mica sandwich structure, traditional metal carrier grid structure and block carrier structure:
1. mica sandwich structure, with small volume, low cost and large heat capacity, is suitable for absorbing large energy in a short time and for single impact at long intervals (once a week).
2. with the traditional metal grid structure, the product has relatively moderate volume, relatively moderate cost and good heat dissipation performance. It is suitable for multiple impacts in a short time (once every 30 minutes). It can be used in crowbar resistor, chopper resistor and braking resistor circuits.
3. block carrier structure, the product has strong impact resistance and good heat dissipation performance. High structural strength and moderate price. Suitable for short-time multiple impact. It can be applied to crowbar resistor, chopper resistor, braking resistor and other circuits.

█ Life Time of Crowbar Resistor

200J 1 times/second  
220KJ 1 times/30mins 35000 times(20 years of life)
640KJ 1 times/week 1000 times(20 years of life)
1360KJ 1 times/month 260 times(20 years of life)
Take 1.5MW windmill generator as an example, environment temperature ≤ 60℃

█ Resistor Material Comparison

 Material

(g/mm3)

(Ω·mm2/m)

J/(g·K)

W/(m·K)

ppm/℃

SUS304

7.9

0.72

0.5

13.2

≤1400

SUS316

7.93

0.78

0.45

13.23

≤900

SUS310S

7.98

0.88

0.46

13.2

≤600

Cr20Ni80

8.4

1.09

0.441

16

≤100

█ Selection Table

Energy

Resistance

Time

Dimension(mm)

(L)mm

(W)mm

(H)mm

50KJ

3R

30mS

420

160

95

200KJ

2R

3.8S

285

178

150

500KJ

3.3R

3.8S

670

150

150

1.0MJ

0.36R

0.1S

395

190

153

1.5MJ

0.45R

3S

520

292

100

2.0MJ

0.4R

30mS

868

175

130

2.0MJ

0.5R

30mS

943

195

135

2.2MJ

0.7R

1S

446

240

153

2.5MJ

0.95R

3S

597

400

200

3.0MJ

0.7R

1S

432

240

153

Note: For other technical parameters & requirements, please contact with our company’s business man.


Product detail pictures:

Special Design for Load Bank Controller - Crowbar/Chopper Resistor – Wepower detail pictures

Special Design for Load Bank Controller - Crowbar/Chopper Resistor – Wepower detail pictures

Special Design for Load Bank Controller - Crowbar/Chopper Resistor – Wepower detail pictures


Related Product Guide:

Together with the "Client-Oriented" enterprise philosophy, a arduous good quality control technique, sophisticated producing equipment and a sturdy R&D staff, we generally offer superior quality merchandise, superb solutions and aggressive rates for Special Design for Load Bank Controller - Crowbar/Chopper Resistor – Wepower , The product will supply to all over the world, such as: Greenland, Ecuador, Swedish, We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information if you have any questions. We are glad to work for every client.
  • We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Laurel from Mexico - 2017.01.11 17:15
    The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Laurel from Argentina - 2017.05.21 12:31