OEM/ODM Supplier Resistor Not Connected To Ground - Rack Mounted Load Bank for data center, UPS – Wepower

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With a positive and progressive attitude to customer's interest, our company continuously improves our product quality to meet the needs of customers and further focuses on safety, reliability, environmental requirements, and innovation of Sizing Of Neutral Grounding Resistor, Guitar Pedal Input Resistor To Ground 1meg, Resistance Brazing Aluminum, In case you are intrigued in any of our products or want to focus on a personalized get, please sense totally free to contact us. We're wanting ahead to forming successful enterprise relationships with new shoppers across the world during the in close proximity to long term.
OEM/ODM Supplier Resistor Not Connected To Ground - Rack Mounted Load Bank for data center, UPS – Wepower Detail:

█ Description:

The most effective approach to power and thermal load testing during commissioning that we have found is to utilize rack-mounted load banks (Figure 2). These are resistive heating element load bank units that mount in typical 19” server racks, plug into dual-circuit rack PDUs (power distribution units), and can be dialed-in to the expected load of the particular rack.  In this manner, the full load rack configuration can be simulated, as well as some partial theoretical/planned initial buildout. The fact that the loads can be configured to match expected loads, and at specific locations, can have a number of benefits to more representative testing. For example, hot aisle hot spots can be better detected, resulting from either airflow variations within the hot aisle or, perhaps, based on variations in performance by in-row cooling hardware. Further, N+1 testing of cooling equipment can be accurately simulated. If, for example, a data center is designed to to have 10 in-row cooling (IRC) units, but only requires 9 operational to meet heat rejection loads (i.e. 9 + 1 = 10), during design load testing, a single IRC can be failed and the hot aisle can be evaluated to determine if unacceptable hot aisle temps result near the failed IRC unit. Performing this kind of testing with floor load banks would be inconclusive at best.

Friendly Notice: we are willing to provide customized products for our customers with their logo.

Using Application: Data Center, Generator, UPS power supply, Inverter, project debugging, Laboratory, etc.

█ Parameters:

Rack Mounted Load Bank table sheet

TWLB-AC220V/6KW

Rated Voltage AC220V(±10%)single phase
Rated Power 6KW
Frequency 50Hz/60Hz
Power step 100W、200W、200W、500W、1KW、2KW、2KW
Control way Manual circuit breaker control
Display Voltage, current LED display
Power fact PF1.0
Accuracy ≤±5%
Display accuracy 0.5
Control power suppluy AC220V/50HZ
Level of protection IP20
Cooling way Forced air, forward wind, backward wind
Color Depending on customers
Dimension W460*D600*H270mm
Weight 30KG
Environment parameters
Working temperature -10℃~+55℃
Relative humidity ≤95%RH
Altitude ≤2500
Pressure 86~106kPa

 

Rack Mounted Load Bank table sheet

TWLB-DC650V/4KW

Rated Voltage

DC650V

Rated Power

4KW

Power step

100W,200W,200W,500W,1KW,2KW

Control way

Manual circuit breaker control

Display

Voltage, current LED display

Accuracy

≤±5%

Display accuracy

0.5级  0.5 degree.

Control power supply

AC220V/50HZ

Level of protection

IP20

Cooling way

Forced air, forward wind, backward wind

Color

Depending on customers

Dimension

W460*D600*H270mm

Weight

30KG

Working temperature

-10℃~+55℃

Relative humidity

≤95%RH

Altitude

≤2500

Pressure

86~106kPa

Optional function

PC control or HMI control

Remarks

For customizing products

Product detail pictures:

OEM/ODM Supplier Resistor Not Connected To Ground - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

OEM/ODM Supplier Resistor Not Connected To Ground - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

OEM/ODM Supplier Resistor Not Connected To Ground - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

OEM/ODM Supplier Resistor Not Connected To Ground - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

OEM/ODM Supplier Resistor Not Connected To Ground - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

OEM/ODM Supplier Resistor Not Connected To Ground - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures


Related Product Guide:

We have now a specialist, efficiency staff to provide good quality company for our consumer. We normally follow the tenet of customer-oriented, details-focused for OEM/ODM Supplier Resistor Not Connected To Ground - Rack Mounted Load Bank for data center, UPS – Wepower , The product will supply to all over the world, such as: Jordan, Lithuania, Panama, When you are keen on any of our goods following you view our product list, be sure to feel free to make contact with us for inquiries. You'll be able to send us emails and get in touch with us for consultation and we shall respond to you as soon as we're able to. If it's convenient, you could find out our address in our web site and come to our enterprise. or additional information of our products by yourself. We're generally ready to build lengthy and steady co-operation relations with any possible shoppers within the associated fields.
  • The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Adam from Austria - 2017.08.18 11:04
    We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Johnny from Pakistan - 2018.06.05 13:10