Hot sale Factory Ground Anti Thunder System Resistor - Rack Mounted Load Bank for data center, UPS – Wepower

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With our outstanding administration, powerful technical capability and strict top quality handle procedure, we go on to provide our purchasers with reliable good quality, reasonable selling prices and excellent services. We goal at becoming certainly one of your most responsible partners and earning your gratification for Resistors To Ground Or Power, Thermal Resistance Aluminum To Aluminum, Generator Load Bank Test, Our firm warmly welcome friends from everywhere in the globe to visit, examine and negotiate business enterprise.
Hot sale Factory Ground Anti Thunder System Resistor - Rack Mounted Load Bank for data center, UPS – Wepower Detail:

█ Description:

The most effective approach to power and thermal load testing during commissioning that we have found is to utilize rack-mounted load banks (Figure 2). These are resistive heating element load bank units that mount in typical 19” server racks, plug into dual-circuit rack PDUs (power distribution units), and can be dialed-in to the expected load of the particular rack.  In this manner, the full load rack configuration can be simulated, as well as some partial theoretical/planned initial buildout. The fact that the loads can be configured to match expected loads, and at specific locations, can have a number of benefits to more representative testing. For example, hot aisle hot spots can be better detected, resulting from either airflow variations within the hot aisle or, perhaps, based on variations in performance by in-row cooling hardware. Further, N+1 testing of cooling equipment can be accurately simulated. If, for example, a data center is designed to to have 10 in-row cooling (IRC) units, but only requires 9 operational to meet heat rejection loads (i.e. 9 + 1 = 10), during design load testing, a single IRC can be failed and the hot aisle can be evaluated to determine if unacceptable hot aisle temps result near the failed IRC unit. Performing this kind of testing with floor load banks would be inconclusive at best.

Friendly Notice: we are willing to provide customized products for our customers with their logo.

Using Application: Data Center, Generator, UPS power supply, Inverter, project debugging, Laboratory, etc.

█ Parameters:

Rack Mounted Load Bank table sheet

TWLB-AC220V/6KW

Rated Voltage AC220V(±10%)single phase
Rated Power 6KW
Frequency 50Hz/60Hz
Power step 100W、200W、200W、500W、1KW、2KW、2KW
Control way Manual circuit breaker control
Display Voltage, current LED display
Power fact PF1.0
Accuracy ≤±5%
Display accuracy 0.5
Control power suppluy AC220V/50HZ
Level of protection IP20
Cooling way Forced air, forward wind, backward wind
Color Depending on customers
Dimension W460*D600*H270mm
Weight 30KG
Environment parameters
Working temperature -10℃~+55℃
Relative humidity ≤95%RH
Altitude ≤2500
Pressure 86~106kPa

 

Rack Mounted Load Bank table sheet

TWLB-DC650V/4KW

Rated Voltage

DC650V

Rated Power

4KW

Power step

100W,200W,200W,500W,1KW,2KW

Control way

Manual circuit breaker control

Display

Voltage, current LED display

Accuracy

≤±5%

Display accuracy

0.5级  0.5 degree.

Control power supply

AC220V/50HZ

Level of protection

IP20

Cooling way

Forced air, forward wind, backward wind

Color

Depending on customers

Dimension

W460*D600*H270mm

Weight

30KG

Working temperature

-10℃~+55℃

Relative humidity

≤95%RH

Altitude

≤2500

Pressure

86~106kPa

Optional function

PC control or HMI control

Remarks

For customizing products

Product detail pictures:

Hot sale Factory Ground Anti Thunder System Resistor - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Hot sale Factory Ground Anti Thunder System Resistor - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Hot sale Factory Ground Anti Thunder System Resistor - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Hot sale Factory Ground Anti Thunder System Resistor - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Hot sale Factory Ground Anti Thunder System Resistor - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures

Hot sale Factory Ground Anti Thunder System Resistor - Rack Mounted Load Bank for data center, UPS – Wepower detail pictures


Related Product Guide:

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Hot sale Factory Ground Anti Thunder System Resistor - Rack Mounted Load Bank for data center, UPS – Wepower , The product will supply to all over the world, such as: Paraguay, Pakistan, Macedonia, Our company has already have pass the ISO standard and we are fully respect our customer 's patents and copyrights. If the customer provides their own designs, We will guarantee that they will be the only one can have that products. We hoping that with our good products can bring our customers a great fortune.
  • This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By Stephanie from Vietnam - 2017.10.27 12:12
    Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Victor from Czech republic - 2017.05.02 11:33